Modbus in scripts¶
This page lets a script read measurements from an energy meter, inverter or other device that speaks Modbus TCP on your network, and show them on AWTRIX. It assumes you know how a script is built. If not, start with Your first script.
Add import modbus to the script. Each app can read its own device, with its own address, port
and unit ID. There is nothing to set up globally. Only reading is supported.
Before you start:
- Enable Modbus TCP on the device you want to read.
- Look up its register list in the manufacturer's manual.
- Note its IP address, the register address, the read function and any scaling factor.
Display a measurement¶
This example reads one holding register every ten seconds. Replace 192.168.1.50 and address 0
with your device's values. It assumes the register holds tenths of a degree: 235 becomes 23.5.
import modbus
class Temperature
var label, next_read, busy
def init()
self.label = "--"
self.next_read = 0
self.busy = false
end
def received(values, error)
self.busy = false
if error != 0
self.label = "--"
log("Modbus error: " + str(error))
return
end
self.label = str(modbus.int16(values[0]) / 10.0)
end
def loop()
if self.busy || now_ms() < self.next_read return end
self.next_read = now_ms() + 10000
self.busy = true
modbus.readHoldingRegisters("192.168.1.50", 0, 1,
/ values, error -> self.received(values, error))
end
def draw()
clear()
text(1, 6, self.label, 0xFFFFFF)
end
end
return Temperature()
How it behaves¶
A read runs in the background, and the display keeps running meanwhile. When the answer arrives,
or the read fails, the callback runs once. On success error is 0. On failure values is nil
and error is the reason code. Start a read in loop(), never in draw(),
and wait for the answer before you start the next one.
Choose what to read¶
All four calls take (host, address, count, callback, opts?):
| Call | Reads | Maximum count |
|---|---|---|
modbus.readHoldingRegisters(...) |
holding registers, function 03 | 125 |
modbus.readInputRegisters(...) |
input registers, function 04 | 125 |
modbus.readCoils(...) |
coils, function 01 | 2000 |
modbus.readDiscreteInputs(...) |
digital inputs, function 02 | 2000 |
hostis an IP address or host name, withouthttp://.addressstarts at zero. If the manual calls the first holding register40001, its address is usually0. Some manuals already give zero-based addresses. Use those as they are.- Addresses run from
0to65535.countis at least1and must not go past65535. - The callback gets a list in address order:
values[0]is the first value you asked for. Registers are numbers from0to65535. Coils and digital inputs are0or1.
opts sets the TCP port and unit ID. Defaults are port 502 and unit 1. Use the unit ID your
device needs, especially behind a gateway.
modbus.readInputRegisters("192.168.1.60", 100, 2,
/ values, error -> self.received(values, error),
{'port': 502, 'unit': 2})
Ports run from 1 to 65535, unit IDs from 0 to 255. Every call can use different settings.
Convert the values¶
Follow the data type and register order in your device's manual:
| Device data type | Conversion |
|---|---|
| unsigned 16-bit integer | values[0] |
| signed 16-bit integer | modbus.int16(values[0]) |
| signed 32-bit integer | modbus.int32(values[0], values[1]) |
| 32-bit float | modbus.float32(values[0], values[1]) |
For a 32-bit value, read two registers. The helpers take the high word first. If your device sends
the low word first, pass values[1], values[0]. Apply scaling afterwards, for example / 10.0 or
/ 1000.0.
Share one device across several apps¶
When several apps show readings from the same device, read once and share the results. A
background script polls the device and publishes
the values through shared. The display apps only read what
they need. This avoids duplicate requests and saves memory.
A module can also use modbus inside a
function an app calls. But a module has no loop(), and calling it from every display app would
still send separate requests. Use a background script for regular polling.
For example, save this background script as meter. It reads two neighboring holding
registers: power in watts and voltage in tenths of a volt. Adjust the host, address and conversion
to your device's manual.
# @headless true
import modbus
class Meter
var next_read, busy
def init()
self.next_read = 0
self.busy = false
end
def received(values, error)
self.busy = false
if error != 0 return end
shared.set("power", values[0])
shared.set("voltage", values[1] / 10.0)
end
def loop()
if self.busy || now_ms() < self.next_read return end
self.next_read = now_ms() + 10000
self.busy = true
modbus.readHoldingRegisters("192.168.1.50", 0, 2,
/ values, error -> self.received(values, error))
end
end
return Meter()
The power app needs no Modbus import. It shows -- if no reading has arrived, or if the last good
reading is more than 30 seconds old:
class Power
var label
def init() self.label = "--" end
def loop()
var age = shared.age("meter.power")
if age != nil && age <= 30000
self.label = str(shared.get("meter.power")) + " W"
else
self.label = "--"
end
end
def draw()
clear()
text(1, 6, self.label, 0xFFFFFF)
end
end
return Power()
For a voltage app, use meter.voltage instead of meter.power and " V" instead of " W". If
you name the background script differently, use that name before the dot.
When a read fails¶
error is 0 on success.
-1: the read could not be done. Check the host, port, Wi-Fi and arguments, and try again at your next interval. Reads can take longer while other apps fetch data.- A positive code comes from the Modbus device. Common ones:
1(unsupported function),2(unknown register),3(unsupported value or count),4(device failure),6(device busy). See the device manual for details.
The web UI's Log tab tells you why. Every failed read writes one line starting with modbus:,
with the reason, the code, how long it took and what was asked of which device:
| Reason | What it means |
|---|---|
response timeout |
The device did not answer within two seconds. |
connection failed |
No connection to that host and port. |
closed without response |
The device closed the connection without answering. |
illegal register address/range |
Code 2: part of the range does not exist on the device. |
offline |
The clock is not connected to Wi-Fi. |
queue full |
Too many reads were waiting at once. Read less often. |
A read of several registers fails with code 2 as soon as one of them does not exist, even when
the first one does. Read a smaller range, or check the register map in the manual. Waiting longer
between reads does not help.