This page lets a script read measurements from an energy meter, inverter or other device that speaks Modbus TCP on your network, and show them on AWTRIX. It assumes you know how a script is built. If not, start with Your first script.

Add import modbus to the script. Each app can read its own device, with its own address, port and unit ID. There is nothing to set up globally. Only reading is supported.

Before you start:

  1. Enable Modbus TCP on the device you want to read.
  2. Look up its register list in the manufacturer's manual.
  3. Note its IP address, the register address, the read function and any scaling factor.

Display a measurement

This example reads one holding register every ten seconds. Replace 192.168.1.50 and address 0 with your device's values. It assumes the register holds tenths of a degree: 235 becomes 23.5.

import modbus

class Temperature
  var label, next_read, busy

  def init()
    self.label = "--"
    self.next_read = 0
    self.busy = false
  end

  def received(values, error)
    self.busy = false
    if error != 0
      self.label = "--"
      log("Modbus error: " + str(error))
      return
    end
    self.label = str(modbus.int16(values[0]) / 10.0)
  end

  def loop()
    if self.busy || now_ms() < self.next_read return end
    self.next_read = now_ms() + 10000
    self.busy = true
    modbus.readHoldingRegisters("192.168.1.50", 0, 1,
      / values, error -> self.received(values, error))
  end

  def draw()
    clear()
    text(1, 6, self.label, 0xFFFFFF)
  end
end

return Temperature()

How it behaves

A read runs in the background, and the display keeps running meanwhile. When the answer arrives, or the read fails, the callback runs once. On success error is 0. On failure values is nil and error is the reason code. Start a read in loop(), never in draw(), and wait for the answer before you start the next one.

Choose what to read

All four calls take (host, address, count, callback, opts?):

Call Reads Maximum count
modbus.readHoldingRegisters(...) holding registers, function 03 125
modbus.readInputRegisters(...) input registers, function 04 125
modbus.readCoils(...) coils, function 01 2000
modbus.readDiscreteInputs(...) digital inputs, function 02 2000
  • host is an IP address or host name, without http://.
  • address starts at zero. If the manual calls the first holding register 40001, its address is usually 0. Some manuals already give zero-based addresses. Use those as they are.
  • Addresses run from 0 to 65535. count is at least 1 and must not go past 65535.
  • The callback gets a list in address order: values[0] is the first value you asked for. Registers are numbers from 0 to 65535. Coils and digital inputs are 0 or 1.

opts sets the TCP port and unit ID. Defaults are port 502 and unit 1. Use the unit ID your device needs, especially behind a gateway.

modbus.readInputRegisters("192.168.1.60", 100, 2,
  / values, error -> self.received(values, error),
  {'port': 502, 'unit': 2})

Ports run from 1 to 65535, unit IDs from 0 to 255. Every call can use different settings.

Convert the values

Follow the data type and register order in your device's manual:

Device data type Conversion
unsigned 16-bit integer values[0]
signed 16-bit integer modbus.int16(values[0])
signed 32-bit integer modbus.int32(values[0], values[1])
32-bit float modbus.float32(values[0], values[1])

For a 32-bit value, read two registers. The helpers take the high word first. If your device sends the low word first, pass values[1], values[0]. Apply scaling afterwards, for example / 10.0 or / 1000.0.

Share one device across several apps

When several apps show readings from the same device, read once and share the results. A background script polls the device and publishes the values through shared. The display apps only read what they need. This avoids duplicate requests and saves memory.

A module can also use modbus inside a function an app calls. But a module has no loop(), and calling it from every display app would still send separate requests. Use a background script for regular polling.

For example, save this background script as meter. It reads two neighboring holding registers: power in watts and voltage in tenths of a volt. Adjust the host, address and conversion to your device's manual.

# @headless true
import modbus

class Meter
  var next_read, busy

  def init()
    self.next_read = 0
    self.busy = false
  end

  def received(values, error)
    self.busy = false
    if error != 0 return end
    shared.set("power", values[0])
    shared.set("voltage", values[1] / 10.0)
  end

  def loop()
    if self.busy || now_ms() < self.next_read return end
    self.next_read = now_ms() + 10000
    self.busy = true
    modbus.readHoldingRegisters("192.168.1.50", 0, 2,
      / values, error -> self.received(values, error))
  end
end

return Meter()

The power app needs no Modbus import. It shows -- if no reading has arrived, or if the last good reading is more than 30 seconds old:

class Power
  var label
  def init() self.label = "--" end
  def loop()
    var age = shared.age("meter.power")
    if age != nil && age <= 30000
      self.label = str(shared.get("meter.power")) + " W"
    else
      self.label = "--"
    end
  end
  def draw()
    clear()
    text(1, 6, self.label, 0xFFFFFF)
  end
end

return Power()

For a voltage app, use meter.voltage instead of meter.power and " V" instead of " W". If you name the background script differently, use that name before the dot.

When a read fails

error is 0 on success.

  • -1: the read could not be done. Check the host, port, Wi-Fi and arguments, and try again at your next interval. Reads can take longer while other apps fetch data.
  • A positive code comes from the Modbus device. Common ones: 1 (unsupported function), 2 (unknown register), 3 (unsupported value or count), 4 (device failure), 6 (device busy). See the device manual for details.

The web UI's Log tab tells you why. Every failed read writes one line starting with modbus:, with the reason, the code, how long it took and what was asked of which device:

modbus: response timeout (-1, 2003ms) reg=100 count=2 unit=3 fc=4 host=192.168.1.60:502
Reason What it means
response timeout The device did not answer within two seconds.
connection failed No connection to that host and port.
closed without response The device closed the connection without answering.
illegal register address/range Code 2: part of the range does not exist on the device.
offline The clock is not connected to Wi-Fi.
queue full Too many reads were waiting at once. Read less often.

A read of several registers fails with code 2 as soon as one of them does not exist, even when the first one does. Read a smaller range, or check the register map in the manual. Waiting longer between reads does not help.